Carbon Equivalent Calculator (IIW, CET, Pcm)

This calculator works out the carbon equivalent of a steel from its chemical analysis using three common formulas: IIW CE, CET and Pcm. Carbon equivalent expresses how strongly the alloying elements raise hardenability, and so the risk of hydrogen cracking in the heat-affected zone after welding.

Inputs

wt%
wt%
wt%
wt%
wt%
wt%
wt%
wt%
Advanced options (1)
wt%

Results

CE (IIW)
0.448
CET
0.333
Pcm
0.273
Weldability (IIW CE guide)
Good weldability; preheat may be needed

    RefENG-MAT-001
    MethodIIW CE; CET (EN 1011-2); Pcm (Ito-Bessyo)
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. IIW carbon equivalentCE = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15CE = 0.18 + 1.4/6 + (0.1 + 0.02 + 0.005)/5 + (0.05 + 0.1)/15 = 0.4483
    2. CET (used in EN 1011-2 preheat method B)CET = C + (Mn + Mo)/10 + (Cr + Cu)/20 + Ni/40CET = 0.18 + (1.4 + 0.02)/10 + (0.1 + 0.1)/20 + 0.05/40 = 0.3332
    3. Pcm (Ito-Bessyo)Pcm = C + Si/30 + (Mn + Cu + Cr)/20 + Ni/60 + Mo/15 + V/10 + 5BPcm = 0.18 + 0.3/30 + (1.4 + 0.1 + 0.1)/20 + 0.05/60 + 0.02/15 + 0.005/10 + 5×0 = 0.2727

    Which formula to use

    The IIW formula is the most widely quoted and suits carbon and carbon-manganese steels with more than about 0.18% carbon. Pcm was developed in Japan for modern low-carbon, microalloyed steels and is more sensitive to boron. CET is the value used by the EN 1011-2 preheat method B, so use it if you are working to that standard.

    All three use weight percent values exactly as reported on a mill certificate or by an optical emission spectrometer.

    Using OES and XRF results

    Optical emission spectrometers report carbon directly, so their results can be entered as they are. Handheld XRF analysers cannot measure carbon, boron or nitrogen reliably; enter carbon from the mill certificate or a separate OES or combustion analysis, otherwise the carbon equivalent will be understated.

    Reading the result

    The weldability rating shown is a general guide based on the IIW value. Actual preheat depends on thickness, heat input and hydrogen level as well as composition, so use the result as an input to a preheat calculation or a qualified welding procedure, not as a substitute for one.

    Assumptions and limits

    • Composition values are in weight percent.
    • Elements left at zero are treated as absent.
    • Weldability bands are general guidance for the IIW value only.

    References

    • International Institute of Welding (IIW) carbon equivalent formula.
    • EN 1011-2, Welding: recommendations for welding of metallic materials, Part 2 (CET).
    • Ito, Y. and Bessyo, K., weldability formula Pcm (1968).

    Questions

    What is a good carbon equivalent for welding?
    An IIW CE of 0.40 or below is generally considered readily weldable without special precautions in moderate thicknesses. Above about 0.45, preheat and low-hydrogen consumables are usually needed.
    Why are my CE and Pcm values so different?
    Pcm gives carbon more weight relative to the alloying elements, so for low-carbon microalloyed steels it is usually much lower than the IIW CE. The two are not interchangeable; compare each against its own limits.
    Can I use this for stainless steel?
    No. Carbon equivalent formulas are for ferritic carbon and low-alloy steels. For stainless steels, use Cr and Ni equivalents and a Schaeffler or WRC-1992 diagram instead.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.