Martensite Start Temperature (Ms) Calculator

The martensite start temperature (Ms) is where austenite begins to transform to martensite on cooling. It guides quenching practice, interpass and post-heating temperatures for hardenable steels, and the risk of quench cracking.

Inputs

wt%
wt%
wt%
wt%
wt%

Results

Martensite start, Ms
305
About 90% martensite at
95.8

    RefENG-MAT-013
    MethodAndrews (1965): Ms = 539 − 423C − 30.4Mn − 17.7Ni − 12.1Cr − 7.5Mo (°C)
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Andrews linear equationMs (°C) = 539 − 423C − 30.4Mn − 17.7Ni − 12.1Cr − 7.5MoMs = 539 − 423×0.4 − 30.4×0.7 − 17.7×1.8 − 12.1×0.8 − 7.5×0.25 = 305.1 °C
    2. Temperature for about 90% martensite (Koistinen-Marburger)T90 = Ms − ln(10)/0.011T90 = 305.1 − 209.3 = 95.78 °C

    Why Ms matters in welding and heat treatment

    Holding a weld above Ms until hydrogen has diffused out, or until the transformation is controlled, reduces cold cracking in hardenable steels. In heat treatment, a low Ms means more retained austenite and greater distortion risk.

    Accuracy

    Empirical equations like this are typically within about ±25 °C for the steels they were fitted to. Austenitising conditions and grain size also affect Ms, so use dilatometry where precision matters.

    Assumptions and limits

    • Fully austenitised before cooling, all alloying in solution.
    • Composition within the range of the Andrews data set.

    References

    • Andrews, K. W., Empirical formulae for the calculation of some transformation temperatures, JISI, 1965.
    • Koistinen, D. P. and Marburger, R. E., Acta Metallurgica, 1959.

    Questions

    What is the Ms of 4140 steel?
    Around 320 to 340 °C, depending on the exact analysis. Enter the heat analysis for a better estimate.
    Does silicon affect Ms?
    Only weakly; the Andrews linear equation leaves it out.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.