Area ratio matters most
A small anode coupled to a large cathode corrodes very quickly; the reverse is usually tolerable. Carbon steel bolts in a stainless steel plate fail fast, while stainless bolts in a carbon steel plate are generally acceptable.
Screening limits
Common design guidance limits the potential difference to about 0.15 V for immersed or harsh conditions, 0.25 V for normal outdoor exposure and 0.5 V for dry, controlled interiors.
Assumptions and limits
- Seawater galvanic series at about 25 °C.
- Metals in electrical contact and wetted by an electrolyte.
References
- ASTM G82, Development and use of a galvanic series for predicting galvanic corrosion performance.
- MIL-STD-889, Dissimilar metals.
Questions
- Can I use stainless steel bolts in aluminium?
- The potential difference is large. It can work in dry conditions with a favourable area ratio, but in wet or marine service isolate the bolts with washers and sleeves.
- Why does stainless steel appear twice?
- Passive stainless steel is noble. In crevices or low-oxygen conditions it can become active, moving it much closer to carbon steel.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.