Larson-Miller Parameter Calculator

The Larson-Miller parameter combines temperature and time into one number for creep. Two tests or service conditions with the same parameter cause roughly the same creep damage, so it is used to extrapolate short high-temperature tests to long service lives, and to estimate remaining life.

Inputs

Results

Larson-Miller parameter
20,956
Equivalent life at T2
501.3

    RefENG-MAT-011
    MethodLMP = T(C + log₁₀ t), T in K, t in hours
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Larson-Miller parameterLMP = T(C + log₁₀ t)LMP = 873.2 K × (20 + log₁₀ 10,000) = 20,956
    2. Equivalent time at T2t2 = 10^(LMP/T2 − C)t2 = 10^(20,956 / 923.2 − 20) = 501.3 h

    Using the equivalent time

    Raising the temperature shortens the time to reach the same parameter. For a typical steel, an increase of 50 °C at around 600 °C cuts life by roughly a factor of 20. This is why small overheating events matter so much for boiler tubes and furnace parts.

    Choosing C

    C is a material constant, typically 20 for ferritic and austenitic steels and between 15 and 25 for other alloys. Where a material standard or creep data set gives a fitted value, use that.

    Assumptions and limits

    • Temperature in kelvin and time in hours inside the formula.
    • Constant stress between the two conditions.

    References

    • Larson, F. R. and Miller, J., A time-temperature relationship for rupture and creep stresses, Trans. ASME, 1952.
    • API 579-1/ASME FFS-1, Part 10 creep assessment.

    Questions

    Does the parameter depend on stress?
    Yes. A master curve plots LMP against stress; this calculator assumes stress is the same in both conditions.
    Is this the same as the Hollomon-Jaffe tempering parameter?
    The equation has the same form but is used for tempering, not creep, and C is usually chosen from carbon content.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.