Using the equivalent time
Raising the temperature shortens the time to reach the same parameter. For a typical steel, an increase of 50 °C at around 600 °C cuts life by roughly a factor of 20. This is why small overheating events matter so much for boiler tubes and furnace parts.
Choosing C
C is a material constant, typically 20 for ferritic and austenitic steels and between 15 and 25 for other alloys. Where a material standard or creep data set gives a fitted value, use that.
Assumptions and limits
- Temperature in kelvin and time in hours inside the formula.
- Constant stress between the two conditions.
References
- Larson, F. R. and Miller, J., A time-temperature relationship for rupture and creep stresses, Trans. ASME, 1952.
- API 579-1/ASME FFS-1, Part 10 creep assessment.
Questions
- Does the parameter depend on stress?
- Yes. A master curve plots LMP against stress; this calculator assumes stress is the same in both conditions.
- Is this the same as the Hollomon-Jaffe tempering parameter?
- The equation has the same form but is used for tempering, not creep, and C is usually chosen from carbon content.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.