Why scaling is approximate
Thinner specimens have less constraint at the notch, so the ductile-to-brittle transition moves to lower temperatures. A sub-size specimen tested at the same temperature can look tougher than the full-size material would be. Several codes compensate by lowering the test temperature for sub-size specimens; check yours.
Assumptions and limits
- Specimen depth 10 mm, notch depth 2 mm, only width reduced.
- Proportional scaling by width.
References
- ISO 148-1, Charpy pendulum impact test.
- ASTM A370 and ASTM E23 sub-size specimen provisions.
- ASME VIII Div 1 UG-84.
Questions
- Is 3/4 size energy multiplied by 4/3?
- Under proportional scaling, yes. Some specifications use a factor of 5/6 on the requirement instead of 3/4.
- Can I convert lateral expansion the same way?
- No, lateral expansion is not scaled linearly; follow the specification.
This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.