Pipe Wall Thickness Calculator

Calculate the wall thickness a pipe needs to contain internal pressure, then add corrosion allowance and the mill under-tolerance to get the minimum nominal wall to specify. Compare the result with standard schedule thicknesses for your pipe size.

Inputs

%

Results

Minimum nominal wall
8.683
Pressure design thickness
6.098
Thickness incl. corrosion allowance
7.598
D/t ratio of pressure thickness
27.6
  • First-principles result. ASME B31.3 eq. 3a adds a Y coefficient; a code option will follow in a later release.

RefENG-PVH-001
MethodBarlow t = P·D / (2S·E); Lamé thick-wall
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Barlow thicknesst = P·D / (2S·E)t = 10 × 168.3 / (2 × 138 × 1) = 6.098 mm
  2. Add corrosion allowance6.098 + 1.5 = 7.598 mm
  3. Allow for mill under-tolerancet_nom = t / (1 − tolerance)7.598 / (1 − 0.125) = 8.683 mm

Barlow formula

Barlow uses the outside diameter and assumes uniform hoop stress through the wall. Using the outside diameter makes it slightly conservative compared with the mean-diameter form, and it is the basis of the pressure design formulas in most piping codes.

Mill tolerance

Seamless and welded pipe is usually allowed to be up to 12.5% thinner than nominal. Dividing by (1 − 0.125) makes sure the thinnest permitted pipe still has the required wall.

Assumptions and limits

  • Internal pressure only; no external loads, bending or thermal stress.
  • Straight pipe; bends and branches need extra checks.

References

  • ASME B31.3, Process Piping, para. 304.1.
  • ASME B31.1, Power Piping.
  • Barlow, P., hoop stress formula.

Questions

Which schedule should I choose?
Pick the lightest standard schedule whose nominal wall is at least the minimum nominal wall shown here, for example from ASME B36.10M tables.
Why does the code formula give a slightly different result?
ASME B31.3 uses t = PD/(2(SEW + PY)), where Y depends on temperature and material. At moderate pressures the difference is small.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.