Vessel Volume and Surface Area Calculator

Calculate the capacity of a vessel or tank with dished ends. The head volume is found by integrating the actual head shape, so torispherical, Klöpper and Korbbogen heads are handled accurately rather than with a rough rule of thumb.

Inputs

Results

Total volume
3,845
Shell volume
3,393
Volume of each head
226.2
Head depth (inside)
300
Overall inside length
3,600
Inside surface area
14.43

    RefENG-PVH-010
    MethodCylinder volume plus head volumes by integration of the head profile
    UnitsSI
    Date2026-11-23

    Working

    Calculated in SI base units; inputs are converted from the units you choose.

    1. Shell volumeV = πD²L / 4V = π × 1.2² × 3 / 4 = 3.393 m³
    2. Head volume (integrated profile)V_head = ∫ π r(x)² dxV_head = 0.2262 m³ = 0.1309 D³; depth = 300 mm
    3. TotalV = V_shell + 2 × V_headV = 3.845 m³ = 3,845 L

    Head volumes at a glance

    For an inside diameter D, a 2:1 ellipsoidal head holds πD³/24 (about 0.131D³), a hemispherical head πD³/12 (about 0.262D³) and an ASME flanged and dished head about 0.081D³. Shell length is measured between tangent lines, where the straight flange of each head begins.

    Straight flange

    Dished heads are made with a short straight flange. If your shell length is measured weld to weld, include the straight flanges in the shell length so they are counted as cylinder volume.

    Assumptions and limits

    • Inside dimensions.
    • Head knuckle and crown radii as standard proportions of the inside diameter.

    References

    • ASME flanged and dished head proportions.
    • DIN 28011 (Klöpper) and DIN 28013 (Korbbogen).

    Questions

    How do I find the volume at a given liquid level?
    Use the horizontal or vertical tank partial volume calculators, which also produce a dip chart.
    Does the surface area include both heads?
    Yes, it is the inside wetted area of the shell plus the heads selected.

    This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.