External Pressure and Vacuum Collapse Calculator

Vessels and tanks under vacuum fail by buckling, not by stress. A shell that easily holds 10 bar of internal pressure can collapse under one atmosphere of external pressure. This calculator estimates the collapse pressure and shows whether stiffening rings are needed.

Inputs

Advanced options (1)

Results

Allowable external pressure
162.8
Elastic collapse pressure
488.5
Critical length (long-tube behaviour beyond)
14.33
Against design pressure
Adequate for the design external pressure
  • Elastic buckling only. Thick shells may yield first, and out-of-roundness reduces strength. Code charts (ASME VIII UG-28, EN 13445) are required for design.

RefENG-PVH-015
MethodWindenburg-Trilling for short shells; Bresse long-tube formula
UnitsSI
Date2026-11-23

Working

Calculated in SI base units; inputs are converted from the units you choose.

  1. Critical lengthLc = 1.11·D·√(D/t)Lc = 14.33 m; L = 3 m, so the shell is short
  2. Short shell (Windenburg-Trilling)Pcr = 2.42E(t/D)^2.5 / ((1 − ν²)^0.75·(L/D − 0.45√(t/D)))Pcr = 488.5 kPa
  3. Allowable pressurePa = Pcr / design factorPa = 488.5 / 3 = 162.8 kPa

Stiffening rings

Collapse pressure rises sharply as the unsupported length falls. Adding rings to reduce L is usually cheaper than thickening the whole shell. Heads count as supports, typically taken one third of the head depth into the head.

Full vacuum

Full vacuum means an external pressure difference of 101.3 kPa (14.7 psi). Vessels that can be steamed out or drained with closed vents often need a full vacuum rating.

Assumptions and limits

  • Perfectly round, elastic, isotropic cylinder.
  • Simply supported ends.

References

  • Windenburg, D. F. and Trilling, C., Collapse by instability of thin cylindrical shells under external pressure, Trans. ASME, 1934.
  • ASME VIII Div 1, UG-28.
  • Timoshenko and Gere, Theory of Elastic Stability.

Questions

What design factor should I use?
A factor of 3 on elastic buckling is common in pressure vessel practice, reflecting sensitivity to imperfections.
Does corrosion allowance matter?
Yes: buckling resistance varies with thickness to the power 2.5, so always use the corroded thickness.

This calculator is a design aid. Check results against the governing code or standard and have critical work verified by a qualified engineer. Read the disclaimer.